London Gather 9 x 6 inch - Ø 125 (61-125-LG6)
Discover the London Gather Hood 9 x 6 inch - Ø 125 by National Flues, an essential accessory for flexible chimney systems. Engineered for optimal performance with Mi-Flex flue liners, this gather hood ensures efficient gas flow, rigorous building regulation compliance, and enhanced safety for wood, coal, gas, and oil appliances. Explore our selection of complementary installation accessories for a complete, high-quality chimney upgrade.
Hover to Zoom / Click for Gallery
Low Stock! – Order Now
£206.49
with free delivery
Give us a call if you find it cheaper and we'll try to price match.
At a Glance
Designed specifically for flexible chimney systems compatible with Mi-Flex 316 and 904 flue liners
Complies with Building Regulations Document J for fully enclosed masonry chimneys
Withstands high temperatures up to 600°C for safe use with wood (under 20% moisture), smokeless coal, gas, and oil appliances
Features a secure adaptor for easy attachment and transition between fireplace opening and flue liner
Engineered for optimal gas flow and efficient chimney performance
×
Email Product
Enter your email address to send the product details:
We Won't Be Beaten On Price
At National Flues, we continuously monitor competitor prices. This ensures that we consistently offer you the best deals on all our products. Here’s how we keep your costs low:
Daily Price Matching: Our team adjusts prices to ensure we stay competitive.
Bulk Purchasing Power: We sell a lot, so we can negotiate better rates with suppliers, passing the savings directly to you.
Operational Efficiency: We have streamlined processes to reduce overhead.
Price Match Guarantee: If you find the same product cheaper within 48 hours, we’ll match it and refund the difference.
Free Delivery Over £100: Orders over £100 are free delivery (call us if delivery is required outside the mainland UK).
“I saved 20% on my purchase compared to other retailers. Exceptional service!” – Jane D.
The London Gather 9 x 6 inch - Ø 125 is a top-quality installation fitting designed to seamlessly integrate with Mi-Flex 316 and 904 flexible flue liners. This gather hood plays a crucial role in forming a complete chimney system when used in conjunction with a flexible flue liner. Building Regulations Document J mandates that flexible flue liners must be fully enclosed within a masonry chimney, and this gather hood ensures compliance and optimal performance.Ideal for use on appliances operating up to 600°C, it’s suitable for wood (with <20% moisture), smokeless coal, gas, and oil.
The gather hood facilitates the transition from fireplace opening to the flexible flue liner. It's designed to sit within the masonry chimney, ensuring no part of the flue liner is exposed, thus maintaining an aesthetic and functional integrity.To secure the bottom fixing, provisions must be made to ensure a gas-tight seal using fire cement, ceramic rope, tape, or high-temperature sealant. Additionally, this gather hood includes an adaptor to easily attach the flexible flue liner, which is crucial for ensuring a secure and efficient fit.
Proper maintenance is essential, including annual sweeping by a competent person, with bi-annual sweeping recommended for solid fuel appliances to prevent blockages and buildup.
SKU: 61-125-LG6
Technical Specifications
Dimension
9 x 6 inch
Flue Liner Compatibility
Mi-Flex 316 & 904
Chimney Size
u00d8 125 mm
Temperature Tolerance
Up to 600u00b0C
Material
High-quality metal
Compliance
Building Regulations Document J
For a secure installation, position the London Gather Hood at the base of the chimney ensuring it fully encloses the flexible flue liner. Use the integrated adaptor for a seamless connection. It is crucial to secure the bottom fixing with a gas-tight seal achieved by applying fire cement, ceramic rope, tape, or a high-temperature sealant. Ensure that the metal flaps are firmly screwed into the masonry brickwork to maintain stability and structural integrity. Regular maintenance, including annual and bi-annual sweeping for solid fuel appliances, is recommended to prevent blockages and build-up.
The primary use of the London Gather Hood is to assist in the smooth transition of gases from the fireplace to the flexible flue liner, ensuring efficient gas flow and compliance with building regulations.
Yes, it is suitable for wood with <20% moisture, smokeless coal, gas, and oil appliances.
It can withstand temperatures up to 600°C, making it suitable for a variety of heating appliances.
The gather hood is attached to the base of the chimney and the metal flaps are folded at right angles and screwed into the brickwork, ensuring a secure fit.
Regular sweeping and inspection are required at least once a year by a competent person, with bi-annual sweeping recommended for chimneys serving solid fuel appliances.
No, building regulations require that the flexible flue liner be fully enclosed in a masonry chimney. Non-masonry enclosures such as timber or plasterboard are not acceptable.
For a gas-tight seal, we recommend using fire cement, ceramic rope, tape, or high-temperature sealant.
Delivery Information +
We work relentlessly to ensure you get your order fast.
Estimated delivery for this product is Wednesday, April 30th.
If you need faster stove or fireplace delivery please give us a call.
We can often reduce longer lead times if we pay the carrier £25 for express delivery.
Visit our Shipping Information page for more information.
Warranty & Returns +
All our products come with warranties. Mi-Flex offers a lifetime guarantee.
Returns for damaged items are covered by insurance; non-damaged returns incur return delivery costs.
Price Match Guarantee +
We will match any price like for like on a retail basis. Give us a call if you find it cheaper and want to buy from us.
Read our review in our London Gather 9 x 6 inch - Ø 125 buyers guide
Introduction
The London Gather Hood 9 x 6 inch - Ø 125 is a premium solution designed to facilitate the smooth transition of gases from your open fireplace to a flexible flue liner. Manufactured by National Flues, this gather hood is engineered to maintain optimum performance and safety in your chimney system. Whether you are updating an existing installation or embarking on a new project, understanding the features, benefits, and the proper installation method is crucial to ensuring a long-lasting and compliant chimney system.
Key Features & Benefits
The London Gather Hood is designed with precision to meet stringent building regulations while offering superior performance. It is certified to operate under extreme temperatures—up to 600°C—making it suitable for wood with less than 20% moisture, smokeless coal, gas, and oil appliances. The integrated adaptor facilitates a secure and easy connection between the fireplace opening and the flue liner, while metal flaps are designed to ensure robust fixation within masonry. This attention to detail not only enhances safety but also ensures that your chimney system operates at peak efficiency.
Importance of Compliance and Safety
Compliance with Building Regulations Document J is not just a legal requirement but a foundation for safe and efficient chimney systems. The London Gather Hood meets these standards by ensuring that the flexible flue liner is completely enclosed within the masonry structure. This setup prevents exposure to external elements, thereby safeguarding the integrity of your chimney and reducing risks associated with heat loss or gas leaks. When installing this gather hood, it is vital to use recommended accessories such as fire cement, ceramic rope, tape, or a high-temperature sealant. These optional accessories are designed to enhance the installation, providing a gas-tight seal that ensures long-term reliability.
Installation Process
The installation of the London Gather Hood is straightforward yet requires attention to detail. First, ensure that the flexible flue liner is properly positioned within the masonry chimney. The adaptor that comes with the gather hood is used to secure the connection between the liner and the fireplace opening, which is then further reinforced using the metal flaps and appropriate fixings. It is highly recommended to use optional accessory products like fire cement and high-temperature sealant to achieve a secure, gas-tight seal at the bottom fixing. This not only prevents leaks but also reinforces the overall safety of the system. Regular maintenance is also essential. A competent person should inspect and sweep the system annually, while bi-annual cleaning is advisable for solid fuel installations to prevent soot or blockage buildup.
Optional Accessories and Enhancements
To ensure a perfect installation, consider exploring our range of optional accessories. Products such as fire cement, ceramic rope, specialized high-temperature sealants, and durable tapes are indispensable tools that add an extra layer of security to your installation. These accessories are designed to work seamlessly with the London Gather Hood, ensuring that every connection is solid and the flue liner remains completely enclosed. They are particularly useful in achieving a gas-tight seal, which is critical for both performance and compliance with building regulations.
Addressing Common Concerns
One of the most common concerns with chimney installations is the fear of gas leaks and inefficiencies in gas flow. The London Gather Hood alleviates these issues by offering a robust design that ensures continuous and unobstructed gas flow while remaining fully enclosed within the masonry. Some may also worry about the complexity of installation, but the design of this gather hood simplifies the process significantly. Detailed installation guidelines and the availability of complementary accessories further reduce the risk of errors. Moreover, the high temperature resilience of the product ensures that even extreme conditions will not compromise its integrity.
Maintenance and Longevity
For the longevity of your chimney system, regular maintenance is indispensable. It is recommended that the gather hood is inspected annually by a competent person. For systems using solid fuel appliances, bi-annual sweeping is advisable to prevent any build-up that could affect performance. By maintaining the system, not only does the safety and efficiency improve, but the overall lifespan of the chimney is also extended. Routine care is the key to avoiding costly repairs down the line and ensuring that the system remains compliant with building standards.
Conclusion
In summary, the London Gather Hood 9 x 6 inch - Ø 125 is an essential component for achieving a safe, efficient, and compliant chimney system. Its robust design, ease of installation with the accompanying adaptor, and ability to work with optional accessories such as fire cement and high-temperature sealants make it a dependable choice for property owners and professionals alike. The product’s high temperature tolerance, compatibility with Mi-Flex flue liners, and the added security of a fully enclosed chimney system underscore its value. With a focus on safety, efficiency, and compliance, this gather hood represents a high-quality investment in your home’s heating system. Upgrade your chimney installation with confidence, knowing that every detail has been engineered for optimal performance.
Buy now or call 01670 206 999.
Compatible and other products that may be of interest...